Welcome to HC OPTICAL!
Hardware system function
Remote maintenance function: can query the running status of all board cards and other information through remote;
Board card maintenance function: the equipment has external DC or AC power input (Note: 1U only has double 48V power supply), double power and double thermal backup;The power supply design has fuse overcurrent, which can be replaced;The board adopts modular design, and all the board cards can be replaced by electricity, easy installation and maintenance.
Equipment alarm function: the equipment has the function of sound and light alarm. When the equipment fails, the ALM light will be red and the buzzer will send out an alarm sound.
Single configuration function
The 1U offers four (0.5U height) service slots, a dual 48V power slot, a master control slot and a fan slot
The 2U offers eight (0.5U height) service slots, two power slots, one master control slot and one fan slot
The 4U offers 16 (0.5U height) service slots, two power slots, one master control slot and one fan slot
Single board card (0.5U) provides 8X8 matrix optical switching function
Provide embedded master network management function
Provide warning indication signal
Provide automatic cooling function of fan board card
Dual power backup + power input monitoring function
Hardware Technical Indicators
The physical picture of 1U device is as follows (2 pieces of 8×8 cards, realizing double 8×8 synchronous switching) :
483mm(L)×240mm(W)×44mm(H)
(1) Operating environment of the equipment
- Ambient temperature: -5℃ ~ +55℃;
- Relative humidity: not more than 85%RH at 25℃;
- Atmospheric pressure: 86 KPa ~ 106 KPa;
- Power supply voltage: -48V/DC±20% (85-264)V/AC;
(2) Power supply
Rated input voltage: -48V /DC 220V/AC.
Power consumption: overall power consumption<10W (full).
(3) Grounding
Communication station: joint ground wire, grounding resistance ≤1Ω, intermediate station: grounding resistance ≤4Ω.
8x8 matrix optical switching board card
Function overview:
The 8X8 optical switching matrix enables strict non-blocking bidirectional cross-connection of 8 (input) ×8 (output) core fiber routing.It plays an important role in optical communication applications.
Specifications and parameters:
Operating wavelength: 1310nm/1550nm;
Intervention loss of optical fiber connector: ≤2.5dB;
Return loss: ≥45dB;
Crosstalk: ≥55dB;
Switching time: ≤50ms;
Operating temperature: -5°C to +55°C;
Storage temperature: -40°C to +70°C;
Humidity requirement: ≦ 85%RH;
Link number: optional MXN links, (0.5U height M+N≤16;1U height M+N≤32);
Master Control Board Card (NMU)
Function overview:
The control board card is used to manage all the board cards of the monitoring station and communicate with the server of the monitoring center.Report the status of the monitoring station to the monitoring center, or implement the configuration and operation instructions issued by the monitoring center.Using the embedded control system, the structure is refined, with the characteristics of flexible communication and convenient maintenance.
Specifications and parameters:
Ethernet interface: 10/100Mbps;
Operating temperature: -10°C to +60°C;
Storage temperature: -40°C to +70°C;