Isolator/WDM Hybrid Combination Spec

The Isolator/WDM Hybrid Combination is a hybrid device that integrates an optical isolator (Isolator) and a wavelength division multiplexer (WDM). It combines the functions of the two devices to achieve both unidirectional transmission of optical signals (isolation of reflected light) and multiplexing and demultiplexing of multi-wavelength signals. This hybrid device is widely used in optical communications, fibre lasers and optical sensing systems.

contact us:lina@glhcoptical.com

 

Features

 

Optical isolation function:
Allows one-way transmission of optical signals, prevents reflected light from returning to the light source, and protects the laser from interference by reflected light.
 
Wavelength Division Multiplexing Function:
Combines optical signals of multiple wavelengths into a single fibre for transmission (multiplexing).
Separates multiple wavelength signals in a single fibre into separate channels (demultiplexing).
 
Signal protection and optimisation:
Improves system stability and reduces noise and signal distortion caused by reflected light.
 
Highly Integrated:
Simplifies optical path design by integrating isolator and WDM functions in a compact device.

 

Applications

 

Optical communication systems:
Fibre optic networks: for long-haul transmission and metropolitan area networks (MANs) to improve signal quality and system reliability.
Data Centre Interconnect: for multi-wavelength transmission and reflected light isolation in high-speed optical modules.
 
Fibre Lasers:
Laser Protection: Prevents reflected light from damaging lasers and improves laser life and stability.
Multi-wavelength laser system: Supports multi-wavelength laser generation and transmission.
 
Optical Sensing Systems:
Distributed Fibre Optic Sensing: for multi-wavelength sensing signal transmission and reflected light isolation.
Environmental monitoring: for high stability optical signal transmission in complex environments.
 
Test & Measurement:
Optical test equipment: for signal isolation and multiplexing in multi-wavelength test systems.
 
Medical Devices:
Laser medical equipment: protection of laser sources and optimisation of signal transmission in laser therapy and diagnostic equipment.

 

 

Technical Specification

 

                                             Parameter

Single Stage

Dual Stage

 

Operating Wavelength   Rangenm

 

Signal Channel

C band:1528~1564 or

L band:1570~1605

Pump Channel

965~995

 

Insertion LossdB

Signal Port

<1.2

<1.3

Pump Port

<0.6

Wavelength Dependent   LossdB

Signal to Common

<0.5

 

 

Wavelength IsolationdB

Signal to Common@Pump Wavelength Range

>30

Pump to Common@Signal Wavelength Range

>12

Reverse Direction Isolation

(over signal wavelength   range,0~70,all sop)

 

Common to Signal

>21

>36

Polarization Dependent   LossdB

<0.1

<0.2

Polarization Mode   Dispersion(standard)ps

<0.25

<0.05

DirectivitydB

≥50

Return LossdB

≥45

Optical PowermW

500

Operating Temperature()

-0~+70

Storage Temperature()

-40~+85

Fiber Type

Signal & Tap Ports

Corning SMF-28

 

Common &Pump Ports

Corning HI1060

Package sizemm

Φ5.5x40

*  900um loose tube fiber available and connectorized process available

 

Dimension (Unit:mm)

 

 

 

 

 

 

 

 