4×8 All-optical Cross Optical Path Module
Features
Low insertion loss
Wavelength range
Low crosstalk
High stability and reliability
Modular design
Applications
System monitoring
Configuration is high
Multiple light monitoring
Laboratory development
Remote optical fiber monitoring system
Technical Parameters
Type no. |
FSW-4X8 |
Test the wavelength |
1550nm |
Insertion loss |
≤1.5dB |
repetitive |
≤0.05dB |
crosstalk |
≥60dB |
Return loss |
≥55dB |
Switch time |
≤10ms(The adjacent channel) |
Switch life |
≥107 |
Optical fiber type |
SM-9/125,900um Pine casing |
The degree of long |
0.5m±0.01m |
The interface type |
LC/UPC |
Control interface |
UART(RS232),Lead length is 0.5 meters |
Working voltage |
+5V |
Power consumption |
≤80W |
Working temperature |
-20 ~ 60 °C |
Storage temperature |
-40 ~ 70 °C |
size |
390mm×270mm×38mm |
Optical Path diagram
There are 12 ports of CH1~CH12, and any two ports can be intercommunicated. For example, CH1 can communicate with any port of CH2~CH12。
Dimension(mm)
Pin Configurations
Pin# |
Signal name |
Type |
Description |
A1 |
VCC |
Power |
+5VDC , Digital power supply |
A2 |
GND |
Power |
Digital ground |
1 |
NC |
NC |
Dangling |
2 |
NC |
NC |
Dangling
|
3 |
RX |
Input(RS232) |
Data reception |
4 |
TX |
Output(RS232) |
Data reception |
5 |
GND |
Power |
Digital ground |